What should be paid attention to in the maintenance of three-dimensional parking equipment?


Published Time:

2023-04-14

Let's explain how to maintain automated parking systems. With the improvement of people's living standards, private cars are increasing, but the problem of difficult parking has become increasingly prominent, becoming a major challenge for large cities. However, the application of automated parking systems has greatly alleviated this situation. Since automated parking garages are very expensive, it is essential to perform good maintenance when using them. Here, I will briefly introduce what needs attention for automated parking garage maintenance. Maintenance personnel should regularly inspect and perform maintenance on automated parking systems, which can be divided into: 1. Weekly Maintenance: Every week, the operating environment, metal structure, electrical equipment, transmission devices, and safety protection devices of the automated parking system should be regularly maintained and cleaned. For areas requiring lubrication, lubricating grease should be added or certain adjustments should be made. Any abnormal situations found should be dealt with immediately. 2. Monthly Maintenance: Every month, the working conditions of various mechanical parts, control systems, and safety protection devices of the automated parking system should be inspected, cleaned, lubricated, and improved. 3. Quarterly Maintenance: In addition to daily inspections, the main load-bearing components of the automated parking system should be handled quarterly.

Let me explain how to maintain and maintain three-dimensional parking equipment?

With the improvement of people's living standards, there are more and more private cars, but the problem of difficulty in parking is becoming more and more prominent, becoming a major problem in big cities. However, the application of three-dimensional parking equipment has greatly alleviated this situation. Because the price of three-dimensional parking garages is very high, when using three-dimensional parking garages, maintenance work must be done. Let me briefly introduce what should be paid attention to in the maintenance of three-dimensional parking garages.

 What should be paid attention to in the maintenance of three-dimensional parking equipment?

Maintenance personnel conduct regular safety inspections and maintenance of three-dimensional parking equipment, which can be divided into:

1. Weekly maintenance

Every week, regular maintenance and cleaning should be carried out on various aspects of the three-dimensional parking equipment, including the use environment, metal structure, electrical equipment, transmission device, and safety protection device. Lubricating grease should be added to areas that require lubrication, or some adjustments should be made. Any abnormalities found should be dealt with immediately.

2. Monthly maintenance

Check, clean, lubricate, and adjust the working conditions of various mechanical parts, control systems, and safety protection devices of the three-dimensional parking equipment every month.

3. Quarterly maintenance

In addition to daily safety inspections, the main load-bearing components and their connections, safety protection devices, product appearance and safety warning signs, warnings, etc., of the three-dimensional parking equipment should be checked and maintained every quarter. If necessary, functional tests should be conducted on the control system.

4. Annual maintenance

Every year, the three-dimensional parking equipment will undergo a comprehensive and comprehensive daily maintenance and cleaning work, including testing the electrical wire joints and grounding resistance of electrical equipment.

Maintenance content and standards:

1. The metal structure parts and the whole should be firmly connected, stable and reliable, without distortion, deformation or welding cracks. There should be no obvious bending or abnormal noise during loading and operation.

2. High-strength bolt connections should be tightened to ensure the tightening torque specified in the regulations. Standard parts, flat washers, and spring washers should be complete, the bolt length should be higher than the nut, and the tightening should be reliable and without loosening.

3. The vertical angle of the overall metal composite material frame column ≤ L/1000mm (L is the length of the metal composite material overall frame column), the flatness between beams ≤ 15mm, the difference in length between the two diagonals of the frame ≤ 10mm, except for special provisions.

4. When a vehicle is carrying the rated load, the rear deflection value of the longitudinal load-bearing wall positioning point should be ≤ L/400mm (L is the length of the beam).

5. The foundation bolts of the column base plate should not be loose or rusted. The foundation stone should not sink or crack, and the surrounding area should be kept clean.